News Center
IR SF6 sanalysis 160 Quantitative

IR SF6 sanalysis 160 Quantitative

Mar 13, 2013The concentration and types of SF 6 in Gas Insulated Switchgear (GIS) play a decisive role in the devices' insulating property. A quantitative analysis of SF 6 and its decompositions can help to find the reason of fault. In order to find the concentration information of some special ramifications of SF 6 from the infrared spectrum of GIS's gas, this paper proposes Particle Swarm ...

[email protected]

News Detail

  • Quantitative infrared spectroscopic analysis of SF6

    May 30, 2001The quantitative analysis of the decomposition products of SF 6, obtained under various electrical stress conditions, was investigated using FT-IR spectroscopy and PLS-calibration. This technique provides the sensitivity necessary to determine reliable concentrations in the low ppm v and for some components even in the sub-ppm v range using aCited by: 21

    Get Price
  • Quantitative infrared spectroscopic analysis of SF6

    Quantitative infrared spectroscopic analysis of SF 6 decomposition products obtained by electrical partial discharges and sparks using PLS-calibrations AuthorCited by: 21

    Get Price
  • The research of quantitative analysis for SF6 and its

    Mar 13, 2013The concentration and types of SF 6 in Gas Insulated Switchgear (GIS) play a decisive role in the devices’ insulating property. A quantitative analysis of SF 6 and its decompositions can help to find the reason of fault. In order to find the concentration information of some special ramifications of SF 6 from the infrared spectrum of GIS’s gas, this paper proposes Particle SwarmAuthor: Yongbiao Zhao, Qilin Zhang

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    Feb 05, 2015Quantitative research on SF 6 decomposition components was conducted in this study based on the FTIR method. The absorption coefficients of several types of SF 6 decomposition components were confirmed, and the quantitative relationships among gas production rate, PD time, and PD quantity were studied.Cited by: 20

    Get Price
  • Quantitative Analysis for SF6 and Its Compositions in GIS

    In this paper, a method for GIS equipment fault diagnosis by the analysis of volume fractions of the derivatives of SF6 gas inside GIS equipment is presented. For the method, based on the differential spectra method, a neural network model and the particle swarm optimization are used for training analysis of infrared spectra, to realize theAuthor: Hailun Wang and Jianwei Shen

    Get Price
  • Analysis of spark decomposition products of SF 6

    Journal of Molecular Structure 480–481 (1999) 211–217 Analysis of spark decomposition products of SF6 using multivariate mid-infrared spectrum evaluation R. Kurte, H.M. Heise*, D. Klockow Institut fu¨r Spektrochemie und Angewandte Spektroskopie, Bunsen-Kirchhoff-Str. 11, D-44139 Dortmund, Germany Received 25 August 1998; accepted 30 September 1998 Abstract Infrared spectroscopy is a

    Get Price
  • QUANTITATIVE INFRARED SPECTROSCOPY Objective: Text

    A discussion or the theory of IR, how IR spectrometers work, the meaning of “fourier tranform” and the quantitative use of IR. Please include diagrams. • Procedure: 5 points Deviations from the manual. • Tables Plots: 15 points Neatly and correctly labeled plots of

    Get Price
  • How can i use FT- IR spectroscopy in quantitative analysis?

    FT- IR spectroscopy used in quantitative analysis of some drugs as ibuprofen. I want to know the principle of this experiment and the response changed by change in the concentration of drug .

    Get Price
  • Quantitative Analytical applications of FTIR Spectroscopy

    Quantitative analysis, Detecting impurities Far 50 – 100 200 – 10 6 × 1012 – 3 × 1011 Analyze structure of molecule Most used 2.5 – 15 144000 - 670 1.2 × 10 – 2 × 1013 Mostly Quantitative analysis PRINCIPLE At temperatures above absolute zero, all the atoms in molecules are in continuous vibration with respect to each other.

    Get Price
  • Quantitative Analysis From Ftir - SlideShare

    May 17, 2009Quantitative Analysis from FTIR spectrometer M. Zafar Iqbal Physical Properties of Polymers Slideshare uses cookies to improve functionality and performance, and to provide you with relevant advertising.

    Get Price
  • Quantitative Analysis for SF6 and its Compositions in GIS

    In this paper, a method for GIS equipment fault diagnosis by the analysis of volume fractions of the derivatives of SF6 gas inside GIS equipment is presented. For the method, based on the differential spectra method, a neural network model and the particle swarm optimization are used for training analysis of infrared spectra, to realize the quantitative analysis of specific derivatives.

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    SOF 2, SO 2 F 2, SO 2, and CO were selected as the characteristic decomposition components for system analysis. The standard infrared absorption spectroscopy of the four characteristic components was measured, the optimal absorption peaks were recorded

    Get Price
  • China Sf6 Gas Leak Detection Device Analysis Portable Sf6

    SF6 quantitative leak detector is easy to operate and carry, and it can detect the minimum concentration of SF6 gas in the air. The main technical structure characteristics of the instrument are its sensitivity, response time and stability, furthermore, it can against humidity and toxic gases.

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    Fourier transform infrared spectroscopy quantitative analysis of SF6 partial discharge decomposition components October 2014 Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    Feb 05, 2015Fourier transform infrared spectroscopy quantitative analysis of SF6 partial discharge decomposition components. Zhang X(1), Liu H(1), Ren J(2), Li J(1), Li X(1). Author information: (1)(a)State Key Laboratory of Power Transmission Equipment System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing

    Get Price
  • Analysis of spark decomposition products of SF6 using

    May 04, 1999Infrared spectroscopy is a powerful tool for the analysis of gaseous by-products generated from electrical discharges in sulfur hexafluoride gas. The spark decomposition of SF 6 was studied under pressures of 250 kPa and 300 kPa, which were provided for the insulating gas inside a discharge chamber constructed from stainless steel and Teflon.

    Get Price
  • FT-IR spectroscopic rapid analysis | DILO GmbH

    The service offered includes the qualitative and quantitative analysis of the components of a gas mixture in the range of 0 to 15 % (accuracy depending on the substances to be analysed).

    Get Price
  • Ultraviolet differential optical absorption spectrometry

    X Zhang et al 3 Lastly, the concentration of CS 2 is detected according to c˜ = F(λ)/(σ˜(λ)L), (4) where c′ is the differential optical absorption concentration, and σ′(λ) is the differential optical absorption cross section. 3. Mechanism of CS 2 and experimental section PD and POF would cause the degradation of epoxy spacer [5]. The typical structure of epoxy spacer is shown in

    Get Price
  • Fouriertransform infrared spectroscopy for

    (A) IR-spectrum of HF in SF6 (top, after decomposition by dependent variation - is expected to exist for HF-line sparks, optical pathlength 10 cm, total pressure 86.6 kPa; the H2O broadening by air and SF6, respectively, the total spectrum below from an experiment with discharge chamber leakage) (B) Spectrum of HF in air, calculated for 100

    Get Price
  • Infrared spectroscopic detection of sulfur hexafluoride

    Absorption by sulfur hexafluoride (SF 6) has been detected in high‐resolution infrared solar spectra of the lower stratosphere and upper troposphere.The identification is based on measurements of the intense, unresolved ν 3 band Q branch at 947.9 cm −1 in solar occultation spectra recorded near 31&N and 47&S latitude by the Atmospheric Trace Molecule Spectroscopy (ATMOS) Fourier

    Get Price
  • Application of infrared spectroscopy to monitoring

    Anal Bioanal Chem (2002) 373 : 639–646 DOI 10.1007/s00216-002-1280-4 S P E C I A L I S S U E PA P E R R. Kurte C. Beyer H. M. Heise D. Klockow Application of infrared spectroscopy to monitoring gas insulated high-voltage equipment: electrode material-dependent SF6 decomposition Received: 11 December 2001 / Revised: 12 February 2002 / Accepted: 20 February 2002 / Published online: 13

    Get Price
  • Ultraviolet differential optical absorption spectrometry

    Oct 12, 2017Zhang X X, Liu H, Ren J B, Li J and Li X 2015 Fourier transform infrared spectroscopy quantitative analysis of SF6 partial discharge decomposition components Spectrochim. Acta

    Get Price
  • Infrared Spectrum Analysis of SF6 and SF6 Decomposition

    Infrared Spectrum Analysis of SF6 and SF6 Decomposition. The experimental conditions and practical aspects for reliable quantitative analysis of reactive sulfurfluoride species are discussed.

    Get Price
  • Cantilever enhanced photoacoustic spectrometry

    Sep 01, 20164. Measurement results and analysis 4.1. Quantitative analysis of trace H 2 S. Using the high-precision gas sample compounder (the largest dilution ratio: 300:1), the 185 μL/L H 2 S/N 2 standard gas is diluted with high-purity N 2 (99.9999%) to 5, 10, 20, 50, 100, and 150 μL/L H 2 S/N 2, which are used as the target gases.

    Get Price
  • Cantilever enhanced photoacoustic spectrometry

    The SF 6 decomposition and its reaction to form H 2 S were simulated.. Quantitative researches on H 2 S were carried out based on CEPAS detection platform.. Detection sensitivity to H 2 S of the detection platform were 0.84 μL/L and 1.75 μL/L.. The influence of temperature and pressure on the detection platform were analyzed.

    Get Price
  • Quantitative analysis using ATR-FTIR Spectroscopy

    concentration of infrared-active compounds. References 1. Boyd S. and Kansiz M. Highest Available Signal-To-Noise Performance, Delivering Superior Sensitivity and Analytical Performance, Advantage Note SI-01353 2. Resolutions Pro Software ‘Help’ files. 3. Harris Daniel C., Quantitative Chemical Analysis, W. H. Freeman, 2006, ISBN 071677041

    Get Price
  • Synthetic Calibration and Quantitative Analysis of Gas

    A method for the quantitative analysis of gas-phase infrared spectra is described in which calibration spectra are calculated from a database of absorption line

    Get Price
  • Wholesale Sf6 Gas Detector, Wholesale Sf6 Gas Detector

    Wholesale Sf6 Gas Detector - Select 2021 high quality Wholesale Sf6 Gas Detector products in best price from certified Chinese Used Metal Detector manufacturers, Gas Detector suppliers, wholesalers and factory on Made-in-China.com