Gas Insulated Switchgear (GIS) has been widely used in substations. The insulating medium used in GIS is sulfur hexafluoride (SF6) gas. However, the internal insulation defect existed in GIS would inevitably lead to partial discharge (PD), and cause the composition of SF6 to SOF2, SO2F2 and SO2 and other characteristic component gases. The decomposition phenomenon would greatly reduce the ...

[email protected]

News Detail

  • SF6 By-products: Safety, Cleaning, and Disposal Concerns

    6 Decomposition and Contamination • Reactive decomposition byproducts form when SF 6 is exposed to: 1. spark discharges, 2. partial discharges, 3. switching arcs, and 4. failure arcing • Decomposition byproducts can take the form of gas or powders • Other types of contaminants can include moisture and air (from handling or leakage),

    Get Price
  • SF6 DIAGNOSTICS AND SOLUTIONS — Powertech Labs

    Sep 01, 2016SF6 DIAGNOSTICS AND SOLUTIONS Sulphur hexafluoride (SF 6) is a non-toxic, odourless gas with unique electrical properties. For over 50 years, it has been used in high-voltage gas-insulated switchgear (GIS), where its excellent dielectric and arc-quenching properties make it an ideal insulating gas for medium- and high-voltage equipment.

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    Nov 01, 2007Under the spark condition, the final toxic products of SF 6 decomposition in the presence of water vapor have been proposed in the literature to be hydrogen fluoride (HF) and sulfur dioxide (SO 2) or sulfuric acid (H 2 SO 4).Cited by: 117

    Get Price
  • Byproducts of Sulfur Hexafluoride (SF6) Use in the

    Decomposition Byproducts and Typical Concentrations During Repeated Sparking Chemical Formula Chemical Name Chemical Abstracts Service Registry Number Experimental Concentration (percent by volume)a HF Hydrogen fluoride 7664-39-3 1.0 SOF 2 (SF 4) b Thionyl sulfide (sulfur tetrafluoride) 7783-42-8 (7783-60-0) 0.5 SOF

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    Sulfur hexafluoride (SF 6) is being widely used in a variety of industrial processes, commercial products and scientific fields due to its unique characteristics such as relatively low toxicity, extreme inertness and high dielectrics.However, the chemically stable gas is one of the most potent greenhouse gases (GHGs) that cause significantly global warming, and has been, thus, blanketed intoCited by: 117

    Get Price
  • SF6 HANDLING PROCEDURE - US EPA

    All in-service SF6equipment shall be assumed to contain decomposition by-products, unless the gas has been tested as safe. When handling gas containing SF6 arc byproducts or solid by- products the following cautions are applicable:

    Get Price
  • Handling and Use of Sulfur Hexafluoride Gas

    B. Decomposition Gasses and Solid By-Products When exposed to sustained or intense electrical arcs, SF6gas decomposes to form sulfur-fluoride gases and metal-fluorides which are toxic. If moisture is present, the decomposition by-products may also include

    Get Price
  • Do’s and Don’ts of SF6 Gas Handling

    Do’s and Don’ts of SF6 Gas Handling Author: Jeff Spoljarick, Dave Smithberger Subject: how ComEd has had success in keeping low emissions rates, and the lessons they have learned; Jeff Spoljarick from ABB and Dave Smithberger from First Energy, presented on the best management practices of SF6

    Get Price
  • MANAGEMENT AND SAFE HANDLING PROCEDURES FOR

    FIST 5-9, Management and Safe Handling Procedures for Sulfur Hexafluoride (SF6) Gas 5. FUNDING NUMBERS 6. AUTHOR(S) Bureau of Reclamation Hydroelectric Research and Technical Services Group Denver, Colorado 7. PERFORMING ORGANIZATIONS NAME(S) AND ADDRESS(ES) Bureau of Reclamation Denver Federal Center PO Box 25007 Denver CO 80225-0007 8.

    Get Price
  • Safe and efficient sf6 handling unit - schallmarkus.de

    MANAGEMENT AND SAFE HANDLING PROCEDURES FOR breaker interruption time; reducing interruption time enhances power system stability. As concerns escalated regarding poly-chlorinated biphenyls (PCBs) that were found in insulating oil used in older breakers, the use of SF6 insulated breakers grew. SF6 is chemically inert, nonflammable, and

    Get Price
  • Material Safety Data Sheet Sulfur Hexafluoride SF

    Chemical Formula: SF6 Odor: Odorless . Specific Gravity (water-1.0): Not applicable . Normal Stable (Conditions to Avoid): Stable under normal conditions. Incompatibilities: Avoid leakage of a liquefied gas such as SF6 onto water or contact hot reactive metals. Hazardous Decomposition Products: Thermal and electrical arc decomposition

    Get Price
  • SF6 Gas Detection For HV GIS Switchgear - Crowcon F-Gas

    Sep 30, 2020Sulphur Hexaflouride (commonly referred to as “SF6”) is an inorganic, colourless, odourless, non-flammable, heavy gas that has exceptional electrical insulation performance. Gas detection is specifed for safe monitoring and measurement of SF6 levels on HV EHV Gas Insulated Switchgear (GIS) and Transformer rooms, 66kV-220kV.

    Get Price
  • SF6 Handling Procedures - P2 InfoHouse

    SF6 Safe Handling Procedures Section 2. Toxicity 2.1. Noncontaminated gas (unused).SF6 gas is odorless, tasteless, colorless, and non-toxic in its pure state. SF6 gas is approximately five times heavier than air and tends to collect in low places, in buildings or

    Get Price
  • Optical technology for detecting the decomposition

    Sulfur hexafluoride (SF6 SF 6) is a reliable insulating gas and has excellent arc-extinguishing properties.

    Get Price
  • Decomposition of high concentration SF6 using an electron

    Jul 01, 2016In this study, high concentration SF 6 (2–10%) was decomposed using an electron beam irradiation. Various influential factors were investigated to improve the destruction and removal efficiency (DRE) of SF 6.The initial concentrations of SF 6, absorbed doses, SF 6 /H 2 ratios and retention times were the main factors of concern. As a result, the DRE increased as the adsorbed dose and

    Get Price
  • Decomposition of SF6–R134a effluents by RF plasma

    Jan 01, 2012Abstract The efficiency of recovery achieved by open or closed loop extraction of RPC exhaust gases is in the range of 90–95% under optimum conditions. For a large detector setup operating on one volume change per day basis, a 5% loss amounts to discharging 50 kg of R134a and 0.5 kg of SF 6 into atmosphere every day.

    Get Price
  • SF6 products | DILO GmbH

    We continually combine the leading technology of our service carts, developed over many years of experience, with the latest customer or market requirements. Whether maintenance is performed on medium voltage switchgear, high voltage switchgear or on gas-insulated lines, our service equipment allows for very easy, safe and economic maintenance.

    Get Price
  • SF6 Reuse – Just another WordPress site

    Handle the insulating gas easily, quickly and safely, realize secondary use of exhaust SF6 gas by removing moisture, impurities, and decomposition in unqualified SF6 gas. Widely used in high-voltage switchgear, circuit breaker, transformer, substation, power station, etc.

    Get Price
  • The SF6 Decomposition Mechanism: Background and

    Gas Insulated Switchgear (GIS) has been widely used in substations. The insulating medium used in GIS is sulfur hexafluoride (SF6) gas. However, the internal insulation defect existed in GIS would inevitably lead to partial discharge (PD), and cause the composition of SF6 to SOF2, SO2F2 and SO2 and other characteristic component gases. The decomposition phenomenon would greatly reduce the

    Get Price
  • Hydrolysis and oxidation on supported phosphate catalyst

    May 20, 2012The activity tests of the catalysts for the decomposition of SF6 were carried out in a fixed-bed catalytic reactor system, as shown in Fig. 2.The gas flow of the reactants, viz. SF 6 and O 2, was controlled by a mass flow controller (MFC, Brooks 5850E) and the steam used as the reactant for the hydrolysis was supplied quantitatively by a syringe pump and saturator.

    Get Price
  • Safe and efficient Sf6 Vacuuming Recovery And Refilling

    Safe and efficient Sf6 Vacuuming Recovery And Refilling instrument. SF6 Gas Filling Device - SF6 Treatment | YUNENG Gas Handling and Refilling Machine widely used in SF6 gas insulated electrical equipment factory, use, operation, scientific research departments and so on, to create a vacuum for a variety of electrical equipment, and fill electric equipment with SF6 gas, and recover SF6 gas

    Get Price
  • SF6 service equipment - GPU-S-2000 - WIKA USA

    The SF 6 service equipment is an efficient and reliable solution that exceeds the current IEC standards for handling SF 6 gas. Low downtimes through long service intervals of more than 2,500 hours make them an extremely durable product that is always ready for use.

    Get Price
  • Adsorption mechanism of SF6 decomposition components onto

    Sep 01, 2018The model of N and F co-doped anatase TiO 2 (1 0 1) surface (NF-TiO 2) and the gas molecules of SO 2, SOF 2 and SO 2 F 2 are established.. The adsorption process of three decomposition components (SO 2, SOF 2 and SO 2 F 2) of SF 6 on certain surface was simulated by DFT method.. The adsorption mechanism for the surface towards gas molecules were analyzed

    Get Price
  • The optimization of SF6 decomposition process using an

    Oct 01, 2018However, in the process of decomposing SF 6 by adding H 2 to increase the decomposition efficiency, corrosion is caused by the generation of hydrogen fluoride as a by-product of the decomposition process (Braun et al., 1987, Chu, 1986, Kim et al., 2013a, Kim et al., 2013b, Son et al., 2016, Tsai, 2007). Titanium is liable to be oxidized and

    Get Price
  • CN101799458A - Method for analyzing decomposition products

    The invention discloses a method for analyzing decomposition products of SF6 in electric equipment. The method comprises the following steps: sampling; and analyzing and detecting a sample with a chromatograph, wherein the detection part of the chromatograph comprises a thermal conductivity detector (TCD) and fission-product detector (FPD) which are in serial connection, the chromatographic

    Get Price
  • Implementation Of Treatment Recovery Of the SF6 Gas

    AVANTEC in their factory, removing the decomposition products. Generally, this paper describes the treatment and the recycling of a used gas. 2/ Introduction Fig.1. Typical 245 kV dead tank circuit breakers using SF6 gas as Fig. 2. Typical Gas Insulated Substation (GIS) 245 kV using SF6 gas as internal insulation and interrupting medium.

    Get Price
  • decomposition, decomposition Suppliers and Manufacturers

    1. Brief Introduction This series of ammonia decomposition generator is composed by decomposition machine, purifier and electric control system. Because of low lost of gas generating, this series of ammonia decomposition generator is specially suitable to be used as accessory equipment of industries mentioned above. 2.