News Center
SF6 Decomposition Reclaim Quantitative

SF6 Decomposition Reclaim Quantitative

High definition Sf6 Gas Density Relay Calibrator - LK403A SF6 Decomposition SO2,HF,H2S Content Purity Moisture Analyzer – Link Electric. Product Detail Connection: Self-sealing quick connector Pressure: 0,5~ 14 bar (gaseous) with automatic flow rate regulation

[email protected]

News Detail

  • SF6 Decomposition in Gas-Insulated Equipment - IEEE

    This paper reviews previous research in SF6 decomposition relating to the operation of gas-insulated switchgears, gas-insulated transmission lines, and electrostatic accelerators. Results on the qualitative and quantitative determination of the by-products and their formation ion rates in various modes of electrical discharges are summarized.

    Get Price
  • Quantitative infrared spectroscopic analysis of SF6

    May 30, 2001The quantitative analysis of the decomposition products of SF 6, obtained under various electrical stress conditions, was investigated using FT-IR spectroscopy and PLS-calibration. This technique provides the sensitivity necessary to determine reliable concentrations in the low ppm v and for some components even in the sub-ppm v range using aCited by: 21

    Get Price
  • Implementation Of Treatment Recovery Of the SF6 Gas

    6gas contains too much decomposition products, due to arc switching, the reclaiming of the gas, on site, with the help of the movable devices is not possible. In this case the gas has to be treated in another way and many reclaiming techniques have been developed

    Get Price
  • Research on Solid Products of SF6 Decomposition Under

    Recent investigations on sulfur hexafluoride decomposition have shown the need of a rapid and efficient method for the qualitative and quantitative analysis of the reaction products.

    Get Price
  • CN103105441B - Qualitative and quantitative analysis

    The invention discloses a qualitative and quantitative analysis method for a sulfur hexafluoride (SF6) gas discharge decomposition product. The method comprises the following steps of: sampling; performing qualitative and quantitative analysis on a sample by a gas chromatograph-mass spectrograph, wherein a quadrupole rod quality detector is adopted, and a chromatographic column is a CP-Sil 5Author: 裘吟君, 陈晓琳, 陈林聪, 张薇, 李欣然

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment - IEEE

    This paper reviews previous research in SF6 decomposition relating to the operation of gas-insulated switchgears, gas-insulated transmission lines, and electrostatic accelerators. Results on the qualitative and quantitative determination of the by-products and their formation ion rates in various modes of electrical discharges are summarized.

    Get Price
  • Strategy for Elimination of SF6 in Production Processes

    Reclaim into “shop” SF6 storage equipment Fill evacuated circuit breaker with the amount of “new” SF6 to be shipped inside the circuit breaker to user (largest units require site assembly and are shipped sealed with dry air –then evacuated and filled with new or reclaimed SF6 at the site) 3

    Get Price
  • CORONA-INDUCED DECOMPOSITION OF SF6 - ScienceDirect

    Jan 01, 2013CORONA-INDUCED DECOMPOSITION OF SF6 R. J. Van Brunt and D. A. Leep* National Bureau of Standards Washington, D. C. 20234 ABSTRACT The stable, neutral decomposition products resulting from positive point-plane dc corona in static SF6 gas have been identified with a gas chromatograph-mass spectrometer.

    Get Price
  • Ultraviolet differential spectroscopy quantitative

    Numerous SF6 decomposition experiments under four kinds of PD generated by four kinds of artificial defects were carried out and the SF6 decomposition products produced by each experiment were

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    Feb 05, 2015Quantitative research on SF 6 decomposition components was conducted in this study based on the FTIR method. The absorption coefficients of several types of SF 6 decomposition components were confirmed, and the quantitative relationships among gas production rate, PD time, and PD quantity were studied.

    Get Price
  • Research on technology of online gas chromatograph for SF6

    In this paper, by virtue of the gas chromatograph-mass spectrometer system, the qualitative as well as quantitative results of SF6 decomposition by-products are presented in 50 Hz AC point-plane

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment

    The increasing application of SF6 as an insulating gas has led to many studies on SF6 decomposition in gas-insulated equipment. In the presence-of an electric arc, spark or corona, SF6 decomposes to a wide variety of chemically active products which possess completely different properties from SF6. The accumulation of these decomposition products in the equipment has caused concerns regarding

    Get Price
  • CN101799458A - Method for analyzing decomposition products

    The invention discloses a method for analyzing decomposition products of SF6 in electric equipment. The method comprises the following steps: sampling; and analyzing and detecting a sample with a chromatograph, wherein the detection part of the chromatograph comprises a thermal conductivity detector (TCD) and fission-product detector (FPD) which are in serial connection, the chromatographic

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    Gas-insulated switchgear (GIS) internal SF 6 gas produces specific decomposition components under partial discharge (PD). By detecting these characteristic decomposition components, such information as the type and level of GIS internal insulation deterioration can be obtained effectively, and the status of GIS internal insulation can be evaluated.

    Get Price
  • SF6 Emissions | SF6 Recovery | SF6 Maintance | Electricity

    The early identification of any decomposition products or moisture within the SF 6 gas will help avoid unnecessary shutdowns, outages and failures, in addition to reducing maintenance expenditure. In order to protect personnel, equipment and the environment regular SF 6 analysis should be adopted within the maintenance schedule.

    Get Price
  • MANAGEMENT AND SAFE HANDLING - Bureau of

    FIST 5-9, Management and Safe Handling Procedures for Sulfur Hexafluoride (SF6) Gas 5. FUNDING NUMBERS 6. AUTHOR(S) Bureau of Reclamation Hydroelectric Research and Technical Services Group Denver, Colorado 7. PERFORMING ORGANIZATIONS NAME(S) AND ADDRESS(ES) Bureau of Reclamation Denver Federal Center PO Box 25007 Denver CO 80225-0007 8.

    Get Price
  • CN103616445A - Analytic method of SF6 decomposition

    The invention discloses an analytic method of SF6 (sulfur hexafluoride) decomposition products. A sample is analyzed through gas chromatography-mass spectrometry. The analytic method disclosed by the invention is capable of performing qualitative and quantitative analysis on compounds by using the characteristic ions of different target compounds as selective ions; in combination with optimal

    Get Price
  • Inorganic volatile fluorides obtained from electrical

    Aug 01, 1979ITALY ABSTRACT Recent investigations on sulfur hexafluoride decomposition have shown the need of a rapid and efficient method for the qualitative and quantitative analysis of the reaction products. An analytical method for characterizing the gas mixture obtai- ned from the decomposition of sulfur hexafluoride in a quartz reactor submitted to an

    Get Price
  • Cantilever enhanced photoacoustic spectrometry

    Sep 01, 20161. Introduction. Sulfur hexafluoride (SF 6) gas-insulated equipment are widely used in high voltage, super-high voltage and ultra-high voltage areas of power system and they are characterized by high reliability, small volume, flexible configuration, low maintenance costs, and others , , .Under ambient temperature and pressure, pure SF 6 is a kind of inert gas with stable chemical properties.

    Get Price
  • Ultraviolet differential optical absorption spectrometry

    SO2F, SOF2, SO2F2 of SF6 decomposition in power equipment Yuwei Fu, Mingzhe Rong, Kang Yang et al.-Chemical kinetic modeling and byproducts in 50 Hz ac point-plane corona discharges Qingqing Gao, Chunping Niu, Xiaohua Wang et al.-Recent citations Ultraviolet Spectral Analysis and Quantitative Detection of Heptafluoroisobutyronitrile (C4F7N) in a

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    A simulated coaxial deterioration chamber was designed and used on the high voltage electrode to re-enact the decomposition of SF6 under the impact of protrusion defect that generates partial

    Get Price
  • Course description CHS239 SF6-Gas Handling and Measuring

    Basic knowledge about SF6-Gas Topics Introduction - Properties of SF6-Gas, environmental aspects - Rules for safe handling of SF6-Gas for operation, mainte-nance and overhaul - Disposal of decomposed SF6-Gas and decomposition products Gas filling and reclaiming procedures - Correct use of SF6-Gas handling devices for filling and reclaiming

    Get Price
  • China High definition Sf6 Gas Density Relay Calibrator

    High definition Sf6 Gas Density Relay Calibrator - LK403A SF6 Decomposition SO2,HF,H2S Content Purity Moisture Analyzer – Link Electric. Product Detail Connection: Self-sealing quick connector Pressure: 0,5~ 14 bar (gaseous) with automatic flow rate regulation

    Get Price
  • Ultraviolet differential optical absorption spectrometry

    Oct 12, 2017The occurrence of partial discharge or partial overthermal fault in sulfur hexafluoride (SF 6)-insulated electrical equipment frequently causes SF 6 and solid insulation materials to decompose into various products. One of the most characteristic products of this process is carbon disulfide (CS 2).The internal fault type and severity of the fault in the insulation equipment can be detected

    Get Price
  • Fourier transform infrared spectroscopy quantitative

    Feb 05, 20151. Spectrochim Acta A Mol Biomol Spectrosc. 2015 Feb 5;136 Pt B:884-9. doi: 10.1016/j.saa.2014.09.109. Epub 2014 Oct 2. Fourier transform infrared spectroscopy quantitative analysis of SF6 partial discharge decomposition components.

    Get Price
  • Cantilever enhanced photoacoustic spectrometry

    The SF 6 decomposition and its reaction to form H 2 S were simulated.. Quantitative researches on H 2 S were carried out based on CEPAS detection platform.. Detection sensitivity to H 2 S of the detection platform were 0.84 μL/L and 1.75 μL/L.. The influence of temperature and pressure on the detection platform were analyzed.

    Get Price
  • IOP Conference Series: Materials Science and Engineering

    2.4.1. Qualitative analysis of SF6 decomposition products. With the help of standard gases, to qualitatively analyze components and special compounds of SF6 decomposition products by use of different detectors and chromatographic column. And then analyze and compare the separation efficiency. 2.4.2. Quantitative analysis of SF6decomposition

    Get Price
  • Edition 3 .0 2019-04 INTERNATIONAL STANDARD NORME

    IEC 60480 Edition 3 .0 2019-04 INTERNATIONAL STANDARD NORME INTERNATIONALE Specifications for the re-use of sulphur hexafluoride (SF6) and its mixtures in electrical equipment

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online